Net Deals Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC control system. HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken ...

  3. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Zone dampers provide automatic control in simple systems while variable air volume (VAV) allows control in sophisticated systems. Smoke and fire dampers. Smoke dampers and fire dampers are found in ductwork where the duct passes through a firewall or firecurtain. Smoke dampers are driven by a motor, referred to as an actuator. A probe connected ...

  4. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    Damper (flow) Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature ...

  5. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    A floor register. A register is a grille with moving parts, capable of being opened and closed and the air flow directed, which is part of a building's heating, ventilation, and air conditioning (HVAC) system. The placement and size of registers is critical to HVAC efficiency. Register dampers are also important, and can serve a safety function.

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.

  7. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. [2] The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to ...

  8. Air Movement and Control Association - Wikipedia

    en.wikipedia.org/wiki/Air_Movement_and_Control...

    The Air Movement and Control Association International, Inc. ( AMCA) is an American trade body that sets standards for Heating, Ventilation and Air Conditioning ( HVAC) equipment. It rates fan balance and vibration, aerodynamic performance, air density, speed and efficiency. AMCA was formed in 1955 from several earlier trade associations which ...

  9. Air preheater - Wikipedia

    en.wikipedia.org/wiki/Air_preheater

    The purpose of the air preheater is to recover the heat from the boiler flue gas which increases the thermal efficiency of the boiler by reducing the useful heat lost in the flue gas. As a consequence, the flue gases are also conveyed to the flue gas stack (or chimney) at a lower temperature, allowing simplified design of the conveyance system ...