Net Deals Web Search

  1. Ad

    related to: fresh air damper formula for gas furnace model ghgd 100 1 2

Search results

  1. Results From The WOW.Com Content Network
  2. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. [2] The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to ...

  3. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    Glossary of HVAC terms. HVAC (heating, ventilation, and air conditioning) is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized ...

  4. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    Damper (flow) Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature ...

  5. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each ...

  6. Annual fuel utilization efficiency - Wikipedia

    en.wikipedia.org/wiki/Annual_fuel_utilization...

    Note that the theoretical limit for a conventional furnace's instantaneous efficiency is 100%, whereas a heat pump used for building heating may exceed 100%. For example, a COP of 1.5 is equivalent to 150%. Heat pumps are readily available for electric and gas sources. [3]

  7. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Heat recovery ventilation. Heat recovery ventilation ( HRV ), also known as mechanical ventilation heat recovery ( MVHR) or energy recovery ventilation ( ERV ), is a ventilation system that recovers energy by operating between two air sources at different temperatures. It is used to reduce the heating and cooling demands of buildings.

  8. Air preheater - Wikipedia

    en.wikipedia.org/wiki/Air_preheater

    The purpose of the air preheater is to recover the heat from the boiler flue gas which increases the thermal efficiency of the boiler by reducing the useful heat lost in the flue gas. As a consequence, the flue gases are also conveyed to the flue gas stack (or chimney) at a lower temperature, allowing simplified design of the conveyance system ...

  9. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    High efficiency condensing gas furnaces typically achieve between 90% and 98% AFUE. [3] A condensing gas furnace includes a sealed combustion area, combustion draft inducer and a secondary heat exchanger. The primary gain in efficiency for a condensing gas furnace, as compared to a mid-efficiency forced-air or forced-draft furnace, is the ...

  1. Ad

    related to: fresh air damper formula for gas furnace model ghgd 100 1 2