Net Deals Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    Damper (flow) Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature ...

  3. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    minimum outside air The lowest amount of fresh air flow that can be allowed into a recirculating system. This limit is set to ensure that the interior air remains safe and comfortable to breathe. outside air damper An automatic louver or damper that controls the fresh air flow into an air handler and modulates to the most energy efficient setting.

  4. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. [2] The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to ...

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate. An important component of natural ventilation is air change rate or air changes per hour : the hourly rate of ventilation divided by the volume of the space.

  6. Building automation - Wikipedia

    en.wikipedia.org/wiki/Building_automation

    Building automation ( BAS ), also known as building management system ( BMS) or building energy management system ( BEMS ), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical, lighting, shading, access control, security systems, and other interrelated systems.

  7. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow. Variable refrigerant flow ( VRF ), also known as variable refrigerant volume ( VRV ), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [ 1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller ...

  8. Airflow - Wikipedia

    en.wikipedia.org/wiki/Airflow

    The damper can be used to increase, decrease or completely stop the flow of air. A more complex device that can not only regulate the airflow but also has the ability to generate and condition airflow is an air handler. Fans also generate flows by "producing air flows with high volume and low pressure (although higher than ambient pressure)."

  9. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC control system. HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [ 1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be ...