Net Deals Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    A floor register. A register is a grille with moving parts, capable of being opened and closed and the air flow directed, which is part of a building's heating, ventilation, and air conditioning (HVAC) system. The placement and size of registers is critical to HVAC efficiency. Register dampers are also important, and can serve a safety function.

  3. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    Damper (flow) Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature ...

  4. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    Glossary of HVAC terms. HVAC (heating, ventilation, and air conditioning) is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized ...

  5. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Volume control dampers An opposed-blade, motor-operated zone damper, shown in the "open" position. Ducting systems must often provide a method of adjusting the volume of air flow to various parts of the system. Volume control dampers (VCDs; not to be confused with smoke/fire dampers) provide this function.

  6. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC control system. HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken ...

  7. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. [2] The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to ...

  8. Bang–bang control - Wikipedia

    en.wikipedia.org/wiki/Bang–bang_control

    In control theory, a bang–bang controller ( hysteresis, 2 step or on–off controller), is a feedback controller that switches abruptly between two states. These controllers may be realized in terms of any element that provides hysteresis. They are often used to control a plant that accepts a binary input, for example a furnace that is either ...

  9. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing ( TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.