Search results
Results From The WOW.Com Content Network
Damper (flow) Opposed blade dampers in a mixing duct. A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature ...
HVAC control system. HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [ 1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be ...
An opposed-blade, motor-operated zone damper, shown in the "open" position. Ducting systems must often provide a method of adjusting the volume of air flow to various parts of the system. Volume control dampers (VCDs; not to be confused with smoke/fire dampers) provide this function.
Most systems will use motorized dampers to control the air mixing, and controlled by the building management system (BMS), or controls system. Typically as the fresh air and exhaust air dampers are driven from 0% open to 100% open, the mixing damper will in turn be driven from 100% open to 0% open, so as to always ensure a constant volume of ...
The Air Movement and Control Association International, Inc. ( AMCA) is an American trade body that sets standards for Heating, Ventilation and Air Conditioning ( HVAC) equipment. It rates fan balance and vibration, aerodynamic performance, air density, speed and efficiency. AMCA was formed in 1955 from several earlier trade associations which ...
Smoke dampers are usually installed by sheet metal contractors. Smoke dampers can be activated by the fire alarm system, usually initiated by smoke detectors, or interlocked with a fire suppression system. Smoke dampers close by an electric or pneumatic actuator, or a spring actuator, and can be either manually reset or driven open on a reset ...
Building automation ( BAS ), also known as building management system ( BMS) or building energy management system ( BEMS ), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical, lighting, shading, access control, security systems, and other interrelated systems.
Air handler. An air handling unit; air flow is from the right to left in this case. Some AHU components shown are. An air handler, or air handling unit (often abbreviated to AHU ), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning ( HVAC) system. [ 1] An air handler is usually a large metal ...